18 May 2007
Low-dose protocol for head CT in monitoring hydrocephalus in children
Krzysztof Rybka, Maria Anna Staniszewska, Tadeusz BiegańskiMed Sci Monit 2007; 13(1): 147-151 :: ID: 482436
Abstract
Background: Children with hydropcephalus and increased intracranial pressure are treated with ventricular shunts. Multiple head CT is used to assess shunt malfunction and changes in ventricular size (volume). Because of the naturally high contrast of the head structures in CT imaging, a low-dose protocol for hydrocephalic pediatric patients was proposed. The aim of the study was to assess the implemented protocol in categories of radiation risk to the patients.
Material and Methods: Head CT examinations were performed using the fourth-generation single-slice scanner PQ-2000 (Picker). Exposure parameters of the routine head procedure stored in the scanner software were the starting point for the investigation. The acceptable ranges of the modified parameters were found on the basis of earlier published results. The effect of the new protocol on image quality was tested using a CATPHAN phantom. The organ doses were evaluated experimentally. The clinical images were evaluated by two experienced and independent radiologists. Results: Head CT examinations were performed in 380 children with hydrocephalus during a 10-year period at the Department of Diagnostic Imaging Polish Mother’s Memorial Hospital. Until 2005 these children were examined according to the routine protocol of the scanner, i.e. 10 mm contiguous axial, 120 kVp, and 225 mAs. Then the protocol was modified to 10 mm contiguous axial, 100 kVp, and 150 mAs. Reductions in patient doses to 70% were found while the clinical images maintained sufficient diagnostic value. Conclusions: The low-dose protocol for head CT can be recommended for the monitoring of pediatric hydrocephalus patients.
Keywords: Adolescent, Child, Child, Preschool, Head - radiography, Hydrocephalus - therapy, Infant, Newborn, Intracranial Hypertension - radiography, Radiation Dosage, Tomography, X-Ray Computed - methods, Ventriculoperitoneal Shunt
Editorial
01 June 2025 : Editorial
Editorial: Harmonization and Publication of the 2025 Updates of the CONSORT and SPIRIT Statements for Clinical TrialsDOI: 10.12659/MSM.949923
Med Sci Monit 2024; 31:e949923
In Press
Database Analysis
Predictive Value of Anion Gap for Acute Kidney Injury Progression and OutcomesMed Sci Monit In Press; DOI: 10.12659/MSM.947405
Clinical Research
Outcomes from Quantitative Flow Ratio-Guided Complete Revascularization and Angiography-Guided Percutaneous...Med Sci Monit In Press; DOI: 10.12659/MSM.948085
Clinical Research
Impact of Tirofiban and Cilostazol on Cardiac Recovery in Elderly Patients with Acute Coronary SyndromeMed Sci Monit In Press; DOI: 10.12659/MSM.947831
Clinical Research
Effects of Weight Loss on Insulin Resistance and Liver Health in T2DM and NAFLD PatientsMed Sci Monit In Press; DOI: 10.12659/MSM.947157
Most Viewed Current Articles
17 Jan 2024 : Review article 9,036,342
Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron VariantDOI :10.12659/MSM.942799
Med Sci Monit 2024; 30:e942799
16 May 2023 : Clinical Research 703,927
Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...DOI :10.12659/MSM.940387
Med Sci Monit 2023; 29:e940387
01 Mar 2024 : Editorial 32,468
Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...DOI :10.12659/MSM.944204
Med Sci Monit 2024; 30:e944204
28 Jan 2024 : Review article 26,520
A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and FutureDOI :10.12659/MSM.943912
Med Sci Monit 2024; 30:e943912