Logo Medical Science Monitor

Call: +1.631.470.9640
Mon - Fri 10:00 am - 02:00 pm EST

Contact Us

Logo Medical Science Monitor Logo Medical Science Monitor Logo Medical Science Monitor

20 May 2010

Iliac artery in-stent restenosis evaluation in 64-row CT

Wojciech Poncyljusz, Aleksander Falkowski, Marcin Sawicki, Monika Rać, Robert Juszkat

Med Sci Monit 2010; 16(1): 43-47 :: ID: 880582

Abstract

Background: The aim of our study was to assess the sensitivity and accuracy of computed tomography angiography (CTA) for the detection of variable degrees of iliac artery in-stent restenosis compared with digital subtraction angiography (DSA).
Material/Methods: Twenty patients (39 women, 43%; 51 men, 57%) with suspected iliac in-stent restenosis were prospectively evaluated with CTA using a 64-row multidetector CT scanner and DSA examination. The patients’ mean age was 63 ±6 years (range, 56 to 81 years). DSA and CTA studies were performed during one hospital stay. Ninety uncovered implanted commercially available stents were suspected of in-stent restenosis: 14 stainless-steel Express Vascular LD, 26 Wallstent, and 50 nitinol Smart stents. Restenosis in the stented segments were divided into four categories: A – minimal intimal hyperplasia in the stented segment <30%; B – hyperplasia obstructing <50% of the lumen diameter in the stented segment; C – hyperplasia obstructing <99% of the lumen diameter in the stented segment; and D – occluding the intimal hyperplasia in the stented segment.
Result: It was possible to visualize the stent diameter, lumen, and degree of in-stent restenosis. Comparisons between CTA and DSA in-stent restenosis in the B, C, and D groups were identical (sensitivity and specificity were 100%). In group A, the sensitivity was 100%, but the specificity was only 80%.
Conclusions: This study demonstrated that 64-row multidetector CTA is a sensitive and accurate noninvasive vascular imaging investigation to detect in-stent restenosis in iliac arteries. Final evaluation needs routine postprocessing analysis. CTA allows radiologists and surgeon to plan corrective endovascular procedures.

Keywords: Iliac Artery, in-stent restenosis, multidetector-CT-angiography, DSA

Add Comment 0 Comments

Editorial

01 January 2025 : Editorial  

Editorial: The Human Cell Atlas. What Is It and Where Could It Take Us?

Dinah V. Parums

DOI: 10.12659/MSM.947707

Med Sci Monit 2025; 31:e947707

0:00

In Press

Laboratory Research  

Comparative Evaluation of the Dimensional Accuracy of Silicone-Based Putty Reline Impressions with Differen...

Med Sci Monit In Press; DOI: 10.12659/MSM.946537  

Clinical Research  

Ankle-Brachial Index as a Predictor of Acute Ischemic Cerebrovascular Event After Central Retinal Artery Oc...

Med Sci Monit In Press; DOI: 10.12659/MSM.945937  

Review article  

COL3A1 Gene Polymorphism and Its Impact on Female Pelvic Organ Prolapse

Med Sci Monit In Press; DOI: 10.12659/MSM.946367  

Clinical Research  

Quantifying Gait Asymmetry in Stroke Patients: A Statistical Parametric Mapping (SPM) Approach

Med Sci Monit In Press; DOI: 10.12659/MSM.946754  

Most Viewed Current Articles

17 Jan 2024 : Review article   6,962,292

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   699,764

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   22,978

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   17,753

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750