MR-angiography as a method for evaluating endovascular coiled cerebral aneurysms

Wojciech Poncyljusz, Janusz Czechowski, Peter Corr, Aleksander Falkowski, Monika Rać

Med Sci Monit 2007; 13(1): 59-64 :: ID: 482380

Abstract

Background: The aim was to compare digital subtraction angiography (DSA) with magnetic resonance angiography (MRA) in evaluating intracranial aneurysms embolized with Guglielmi Detachable Coils (GDCs) and to assess 3D TOF MRA source data, maximum intensity projection (MIP), and 3D iso-surface reconstruction in the follow-up of patients with cerebral aneurysms treated with GDC.Material and Methods: 3D TOF MRA source data, MIPs, and 3D iso-surface reconstructions of 32 GDC coiled aneurysms were compared with DSA images in the follow-up of 28 patients. Images were assessed for parent and branch artery flow, the presence of neck recurrence, and aneurysm regrowth.Results: In the DSA follow-ups of the 32 aneurysms there was no flow in the embolized aneurysm in 20 (62.5%), flow between the coil loops was found in 11 (34%), and the neck flow was observed in 8 (25%). There was good correlation for all these features when the 3D iso-surface MRA and source data were compared with DSA. The correlation between MIP MRA and DSA was less robust. The correlation was very good in 21 of the 32 aneurysms (65.62%), good in 6 (18.75%), acceptable in 3 (9.37%), and weak and non-diagnostic in 2 (6.25%). Additional information can be obtained by performing plain film x-rays of the skull to demonstrate a change in the coil ball configuration. MRA did not detect any residual aneurysm neck in 2 cases.
Conclusions: MRA is a promising technique to evaluate GDC coiled cerebral aneurysms; however, it cannot substitute DSA.

Keywords: Angiography, Digital Subtraction - methods, Diagnosis, Differential, Embolization, Therapeutic - methods, Intracranial Aneurysm - therapy, Magnetic Resonance Angiography - methods, Regional Blood Flow

Add Comment 0 Comments

Editorial

01 June 2025 : Editorial  

Editorial: Harmonization and Publication of the 2025 Updates of the CONSORT and SPIRIT Statements for Clinical Trials

Dinah V. Parums

DOI: 10.12659/MSM.949923

Med Sci Monit 2024; 31:e949923

In Press

Database Analysis  

Predictive Value of Anion Gap for Acute Kidney Injury Progression and Outcomes

Med Sci Monit In Press; DOI: 10.12659/MSM.947405  

Clinical Research  

Outcomes from Quantitative Flow Ratio-Guided Complete Revascularization and Angiography-Guided Percutaneous...

Med Sci Monit In Press; DOI: 10.12659/MSM.948085  

Clinical Research  

Impact of Tirofiban and Cilostazol on Cardiac Recovery in Elderly Patients with Acute Coronary Syndrome

Med Sci Monit In Press; DOI: 10.12659/MSM.947831  

Clinical Research  

Effects of Weight Loss on Insulin Resistance and Liver Health in T2DM and NAFLD Patients

Med Sci Monit In Press; DOI: 10.12659/MSM.947157  

Most Viewed Current Articles

17 Jan 2024 : Review article   9,036,342

Vaccination Guidelines for Pregnant Women: Addressing COVID-19 and the Omicron Variant

DOI :10.12659/MSM.942799

Med Sci Monit 2024; 30:e942799

0:00

16 May 2023 : Clinical Research   703,927

Electrophysiological Testing for an Auditory Processing Disorder and Reading Performance in 54 School Stude...

DOI :10.12659/MSM.940387

Med Sci Monit 2023; 29:e940387

0:00

01 Mar 2024 : Editorial   32,468

Editorial: First Regulatory Approvals for CRISPR-Cas9 Therapeutic Gene Editing for Sickle Cell Disease and ...

DOI :10.12659/MSM.944204

Med Sci Monit 2024; 30:e944204

0:00

28 Jan 2024 : Review article   26,520

A Review of IgA Vasculitis (Henoch-Schönlein Purpura) Past, Present, and Future

DOI :10.12659/MSM.943912

Med Sci Monit 2024; 30:e943912

0:00

Your Privacy

We use cookies to ensure the functionality of our website, to personalize content and advertising, to provide social media features, and to analyze our traffic. If you allow us to do so, we also inform our social media, advertising and analysis partners about your use of our website, You can decise for yourself which categories you you want to deny or allow. Please note that based on your settings not all functionalities of the site are available. View our privacy policy.

Medical Science Monitor eISSN: 1643-3750
Medical Science Monitor eISSN: 1643-3750